IEC 60034-2-3:2020 Rotating electrical machines – Part 2-3: Specific test methods for determining losses and efficiency of converter-fed AC motors. This part of IEC 60034 specifies test methods and an interpolation procedure for determining losses and efficiencies of converter-fed motors within the scope of IEC 60034-1 :201 7. The motor is then part of a variable frequency power drive system (PDS) as defined in IEC 61 800-9-2:201 7. Applying the approach of the comparable converter, the motor efficiency determined by use of this document is applicable for comparison of different motor designs only. The document also specifies procedures to determine motor losses at any load point (torque, speed) within the base speed range (constant torque range, constant flux range) based on determination of losses at seven standardized load points. This procedure is applicable to any variable speed AC motor (induction and synchronous) rated according to IEC 60034-1 :201 7 for operation on a variable frequency and variable voltage power supply. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60034-1 :201 7, Rotating electrical machines – Part 1: Rating and performance IEC 60034-2-1 :201 4, Rotating electrical machines – Part 2-1: Standard methods for determining losses and efficiency from tests (excluding machines for traction vehicles) IEC 61 000-2-4:2002, Electromagnetic compatibility (EMC) – Part 2-4: Environment – Compatibility levels in industrial plants for low-frequency conducted disturbances IEC 61 800-9-2:201 7, Adjustable speed electrical power drive systems – Part 9-2: Ecodesign for power drive systems, motor starters, power electronics and their driven applications – Energy efficiency indicators for power drive systems and motor starters 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 60034-1 :201 7, IEC 60034-2-1 :201 4 as well as the following apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses: • IEC Electropedia: available at http://www.electropedia.org/ • ISO Online browsing platform: available at http://www.iso.org/obp 3.1 motor losses with converter supply when powered by a converter, motor losses are a combination of losses caused by fundamental frequency and losses caused by the converter high frequencies 3.2 fundamental losses fundamental losses in the motor...
Download Address
Download