ISO 13163:2021 Water quality — Lead-210 — Test method using liquid scintillation counting. 6 Procedure 6.1 Sample preparation for measurement Filter and acidify the samples and a blank sample prepared with ultrapure wateras specified in Clause 5. A minimum of 1 blank sample per batch is required. However, the average of several blanks can be used. Measuring blank samples at regular interval enables to rapidly detect a background issue when measuring the samples (see quality assurance and quality control program in Clause 7). Purify the sample from potential interferents. Examples of purification methods are described in Annex A. Determine the chemical recovery. 6.2 Sample measurement Measure 210Pb in the samples by LSC by following the instructions provided by the instrument manufacturer and the steps described in ISO 19361. 7 Quality assurance and quality control program 7.1 General Quality control operations shall meet the requirements of lSO/IEC 17025. Measurement methods shall be performed by suitably skilled staff under a quality assurance program. 7.2 Variables that could influence the measurement Special care shall be taken in order to limit as much as possible the influence of parameters that can bias the measurement and lead to a non-representative result. Failure to take sufficient precautions can require corrective factors to be applied to the measured result. Sampling, transportation and storage, reagents, transfer, measurement of stable lead, and the activity measurement of 210Ph are all subject to potential interference or variability. The presence of chemiluminescence prevents the accurate measurement of the samples. To reduce the chemiluminescence, the samples are left in the dark for a few hours before counting them. This delay can be the same as used for progeny decay as mentioned in Clause 4. If a chemiluminescence peak is observed, wait until the chemiluminescence has decayed and re-count the samples. Preconcentration step of lead is performed using an Fe(llI) co-precipitation, which allows the elimination of Group 1 elements such as K and Na. The chromatographic extraction resin, e.g. an 18C6 crown ether-type resin, has very low affinity for Group 2 elements when choosing appropriate chemical conditions. If these elements are present at high concentrations, the volume of the 18C6 crown ether-type resin column can be revised to cope with their interferences given that the working lead capacity of the 18C6 crown ether-type resin is about 20 mg Phg1 of dry resin. If a cation exchange resin is used for the preconcentration step instead...
Download Address
Download